Fluke MET/CAL Procedure ============================================================================= INSTRUMENT: AVO AVOMETER 2001: (1 year) CAL VER /5520 DATE: 27-Aug-97 AUTHOR: Fluke Corporation REVISION: $Revision: 1.1 $ ADJUSTMENT THRESHOLD: 70% NUMBER OF TESTS: 41 NUMBER OF LINES: 135 CONFIGURATION: Fluke 5520A ============================================================================= # # Source: # Specifications # # Compatibility: # 5500/CAL 5.0 or MET/CAL 5.0 or later # # Subprocedures: # None # # Required Files: # None # # System Specifications: # TUR calculation is based on specification interval of the accuracy file. # The default 5520A accuracy file contains 90 day specs. # # Fluke makes no warranty, expressed or implied, as to the fitness # or suitability of this procedure in the customer's application. # STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 DISP {Procedure not formally tested with UUT.} 1.001 DISP {See procedure README file.} 1.002 ASK- N P J F W 1.003 ASK+ K 1.004 HEAD PRELIMINARY INSTRUCTIONS 1.005 DISP [32] WARNING 1.005 DISP HIGH VOLTAGE is used or exposed during the performance 1.005 DISP of this calibration. DEATH ON CONTACT may result if 1.005 DISP personnel fail to observe safety precautions. 1.006 HEAD {RESISTANCE TESTS} 1.007 DISP Connect the 5520A and the UUT as follows: 1.007 DISP [32] 5520A AUX Hi to UUT + 1.007 DISP [32] 5520A AUX LO to UUT - 1.007 DISP [32] 5520A NORMAL Hi to UUT + 1.007 DISP [32] 5520A NORMAL LO to UUT - 1.008 HEAD RESISTANCE TESTS: {200 Ohm Range} 1.009 5520 200 100.0Z 0.25% 0.2U CW 2.001 HEAD RESISTANCE TESTS: {2 kOhm Range} 2.002 5520 2 1.000kZ 0.25% 0.001U CW 3.001 HEAD RESISTANCE TESTS: {20 kOhm Range} 3.002 5520 20 10.00kZ 0.25% 0.01U CW 4.001 HEAD RESISTANCE TESTS: {200 kOhm Range} 4.002 5520 200 100.0kZ 0.25% 0.1U CW 5.001 HEAD RESISTANCE TESTS: {2000 kOhm Range} 5.002 DISP Connect the 5520A and the UUT as follows: 5.002 DISP [32] 5520A NORMAL Hi to UUT + 5.002 DISP [32] 5520A NORMAL LO to UUT - 5.003 5520 2000 1000kZ 0.25% 1U 2W 6.001 HEAD RESISTANCE TESTS: {20 MOhm Range} 6.002 5520 20 10.00MZ 2.00% 0.01U 2W 7.001 HEAD {DIODE TEST} 7.002 DISP 7.002 DISP [32] Set UUT to DIODE TEST 7.003 5520 1.000V 1.0% 0.001U 2W 8.001 HEAD {DC VOLTAGE TESTS} 8.002 HEAD DC VOLTAGE TESTS: {200mV Range} 8.003 5520 200 190.0mV 0.25% 0.1U 2W 9.001 HEAD DC VOLTAGE TESTS: {2V Range} 9.002 5520 2 1.900V 0.25% 0.001U 2W 10.001 HEAD DC VOLTAGE TESTS: {20V Range} 10.002 5520 20 19.00V 0.25% 0.01U 2W 11.001 5520 20 -19.00V 0.25% 0.01U 2W 12.001 HEAD DC VOLTAGE TESTS: {200V Range} 12.002 5520 200 190.0V 0.25% 0.1U 2W 13.001 HEAD DC VOLTAGE TESTS: {1000V Range} 13.002 5520 1000 1000V 0.25% 1U 2W 14.001 HEAD {AC VOLTAGE TESTS} 14.002 HEAD AC VOLTAGE TESTS: {200mV Range} 14.003 5520 200 190.0V 1.0% 0.3U 60H SI 2W 15.001 5520 200 190.0V 1.0% 0.3U 1kH SI 2W 16.001 HEAD AC VOLTAGE TESTS: {2V Range} 16.002 5520 2 1.900V 1.0% 0.003U 60H SI 2W 17.001 5520 2 1.900V 1.0% 0.003U 1kH SI 2W 18.001 HEAD AC VOLTAGE TESTS: {20V Range} 18.002 5520 20 19.00V 1.0% 0.03U 60H SI 2W 19.001 5520 20 19.00V 1.0% 0.03U 1kH SI 2W 20.001 HEAD AC VOLTAGE TESTS: {200V Range} 20.002 5520 200 190.0V 1.0% 0.3U 60H SI 2W 21.001 5520 200 190.0V 1.0% 0.3U 1kH SI 2W 22.001 HEAD AC VOLTAGE TESTS: {1000V Range} 22.002 5520 1000 750V 1.0% 3U 60H SI 2W 23.001 5520 1000 750V 1.0% 3U 400H SI 2W 24.001 HEAD {DC MILLIAMP TESTS} 24.002 DISP Connect the 5520A and the UUT as follows: 24.002 DISP [32] 5520A AUX Hi to UUT mA 24.002 DISP [32] 5520A AUX LO to UUT - 24.003 HEAD DC MILLIAMP TESTS: {0.2mA Range} 24.004 5520 0.2 0.1900mA 0.75% 0.0001U 2W 25.001 HEAD DC MILLIAMP TESTS: {2mA Range} 25.002 5520 2 1.900mA 0.75% 0.001U 2W 26.001 HEAD DC MILLIAMP TESTS: {20mA Range} 26.002 5520 20 19.00mA 0.75% 0.01U 2W 27.001 HEAD DC MILLIAMP TESTS: {200mA Range} 27.002 5520 200 190.0mA 0.75% 0.1U 2W 28.001 HEAD DC MILLIAMP TESTS: {2000mA Range} 28.002 5520 2000 1900mA 0.75% 1U 2W 29.001 HEAD {AC MILLIAMP TESTS} 29.002 HEAD AC MILLIAMP TESTS: {0.2mA Range} 29.003 5520 0.2 0.1900mA 1.50% 0.0003U 60H SI 2W 30.001 5520 0.2 0.1900mA 1.50% 0.0003U 400H SI 2W 31.001 HEAD AC MILLIAMP TESTS: {2mA Range} 31.002 5520 2 1.900mA 1.50% 0.003U 60H SI 2W 32.001 5520 2 1.900mA 1.50% 0.003U 400H SI 2W 33.001 HEAD AC MILLIAMP TESTS: {20mA Range} 33.002 5520 20 19.00mA 1.50% 0.03U 60H SI 2W 34.001 5520 20 19.00mA 1.50% 0.03U 400H SI 2W 35.001 HEAD AC MILLIAMP TESTS: {200mA Range} 35.002 5520 200 190.0mA 1.50% 0.3U 60H SI 2W 36.001 5520 200 190.0mA 1.50% 0.3U 400H SI 2W 37.001 HEAD AC MILLIAMP TESTS: {2000mA Range} 37.002 5520 2000 1900mA 1.50% 3U 2W 38.001 HEAD {DC AMP TESTS} 38.002 DISP Connect the 5520A and the UUT as follows: 38.002 DISP [32] 5520A 20A Hi to UUT 10A 38.002 DISP [32] 5520A AUX LO to UUT - 38.003 HEAD DC AMP TESTS: {10A Range} 38.004 5520 10 10.00A 1.00% 0.01U HC 2W 39.001 HEAD {AC AMP TESTS} 39.002 HEAD AC AMP TESTS: {10A Range} 39.003 5520 10 10.00A 1.50% 0.03U 60H SI HC 2W 40.001 5520 10 10.00A 1.50% 0.03U 400H SI HC 2W 41.001 END